Wide-range temperature cycling for reliability and thermal-shock testing

Wide-range hot and cold environmental chamber by Ozmist Food, Greater Noida — –40°C to +180°C thermal cycling for reliability testing

The Ozmist Food Hot & Cold Chamber is a wide-range temperature-only environmental test chamber for thermal-cycling reliability studies, low-temperature electronics evaluation, elastomer brittleness testing, and temperature-shock characterisation. Working range –40°C to +180°C (–70°C variant available) with programmable ramp rates up to 8 K/min. Cascade refrigerant cooling with hot-gas defrost, resistive heating, and PID + adaptive-tuning temperature control deliver ±0.5°C stability. Compliance to IEC 60068-2-1 (cold), 60068-2-2 (dry heat), and 60068-2-14 (change of temperature) is built into pre-loaded recipes. Standard volumes 100 L, 250 L, 500 L, 1000 L. Manufactured at Ozmist’s Greater Noida facility with NABL-traceable calibration and IQ/OQ documentation on request.

Key Features

  • Temperature range –40°C to +180°C (–70°C variant)
  • Ramp rate up to 8 K/min (linear over central range)
  • Cascade refrigerant cooling; hot-gas defrost
  • ±0.5°C stability; ±2°C uniformity
  • AISI 304 interior; magnetic-strip sealed door
  • IEC 60068-2-1 / -2 / -14 pre-loaded recipes
  • PLC + HMI; up to 100 programs of 30 segments
  • Cable port for powered/monitored samples
  • USB + Ethernet data export
  • Independent over- and under-temperature interlocks

Technical Specifications

Technical specifications
ParameterValue
Internal volume100 / 250 / 500 / 1000 L
Temperature range–40°C to +180°C (–70°C variant)
Stability±0.5°C
Uniformity±2°C
Ramp rateup to 8 K/min average
RefrigerationCascade R-404A / R-508B
Interior materialAISI 304 stainless
Cable port50 mm silicone-sealed feed-through
ControlPLC + HMI; 100 programs × 30 segments
Data exportUSB + Ethernet CSV
SafetyOver/under-temp interlocks, door interlock
Power supply415 V / 50 Hz three-phase
Warranty24 months full unit; 12 months compressor

Real-World Industrial Applications

The Hot & Cold Chamber is deployed across a diverse set of Indian industrial and commercial contexts. What follows is a set of expert application briefs prepared by our engineering team, each describing the operating problem, the applicable Indian and international standards, and how Ozmist's configuration is engineered to meet it.

Every application description references peer-reviewed research or a named regulatory standard so procurement teams, quality engineers, and plant managers can validate the claims against their own audit expectations. Sources are cited in the References section at the end of this page. If your application does not match one of the profiles below, contact our engineering team via the quote form — the majority of custom Ozmist installations begin with a spec conversation rather than a datasheet pick.

IEC 60068-2-14 Change of Temperature (Thermal Cycling)

Electronics reliability · IEC 60068-2-14

IEC 60068-2-14 test Na (rapid change) and Nb (gradual change) subject products to alternating hot and cold conditions to reveal solder joint fatigue, differential thermal expansion damage, and hermetic seal failures. Automotive electronics, aerospace assemblies, and industrial controls routinely require several hundred thermal cycles for qualification. Ozmist chambers with 8 K/min ramp rate accomplish typical Na test cycles in under 3 hours per cycle — meaningful when 500+ cycles are required.

Automotive Electronic Module Qualification

Automotive electronics · AEC-Q100, AEC-Q200

Automotive AEC-Q100/Q200 stress-test flows require thermal-cycle and high-temperature-storage testing. Under-hood modules see –40°C to +125°C; passenger-compartment modules see –40°C to +85°C. Ozmist chambers support both envelopes with the reliability ramp rates AEC test flows demand. Indian automotive suppliers use these chambers for both R&D validation and periodic production audit sample testing.

Battery and Cell Testing

Battery / e-mobility

Lithium-ion cell and battery-pack characterisation across the operating envelope — capacity fade at low temperature, thermal safety at high temperature, cycle life at cyclic temperature — all require wide-range thermal chambers. Ozmist supplies EV, e-mobility, and energy-storage developers with hot-and-cold chambers, often with reinforced cable ports for high-current bias and cell-level monitoring.

Elastomer and Polymer Brittleness Testing

Polymer / rubber testing · ASTM D746

ASTM D746 brittleness temperature testing of elastomers and plastics requires cooling to test temperatures down to –70°C. Ozmist’s low-temperature variant supports these tests without external cryogens (unlike liquid-nitrogen-only competitors). Used by tyre, rubber-goods, and cable-jacketing manufacturers.

Aerospace and Defence Reliability

Aerospace / defence · MIL-STD-810G/H

MIL-STD-810 method 501/502 (high/low temperature) and method 503 (temperature shock) are widely used in Indian defence and aerospace qualification. Ozmist supplies DRDO labs and aerospace suppliers with chambers meeting these test conditions, including reinforced construction for large payload testing.

Performance & Industry Data

Research-backed data supporting product selection, sizing, and ROI planning. Every chart includes a "View data table" button for accessible screen-reader access to the underlying numbers, and a source citation.

Comparative & Reference Data Tables

Model working range and ramp
ModelRangeAvg ramp
HC-100–40 to +180°C5 K/min
HC-250–40 to +180°C8 K/min
HC-500–40 to +180°C6 K/min
HC-1000–40 to +180°C4 K/min
HC-250-LT–70 to +180°C6 K/min
Source: Ozmist Hot-Cold Chamber datasheet
IEC 60068 cold and dry-heat severities
TestSeverityDuration
60068-2-1 Ab-25°C16 h
60068-2-1 Ad-40°C96 h
60068-2-2 Bb55°C16 h
60068-2-14 Nb-40 to +85°C, 3 K/min5–50 cycles
Source: IEC 60068-2-1 / -2 / -14

Further performance and application data

Frequently Asked Questions

References

  1. IEC 60068-2-1, 2-2, 2-14. Environmental testing.
  2. AEC-Q100. Failure Mechanism Based Stress Test Qualification for Integrated Circuits.
  3. MIL-STD-810H. Test Method Standard, Environmental Engineering Considerations and Laboratory Tests.
  4. ASTM D746. Standard Test Method for Brittleness Temperature of Plastics and Elastomers.

Get a Quote

Interested in the Hot & Cold Chamber?

Send us your capacity, delivery state, and site requirements. Our engineering team will respond with a spec proposal and price within 24 business hours.

Request Quote

Hot & Cold Chamber
Get pricing and specification from Ozmist

Get Quote